3KW Hybrid Inverter with Charger

Features and function:1.Pure sine wave output2.CPU control technology; SCM control 3.Strong ability of impact resistance4.Have UPS function and AC charger function5.Wide input voltage range: 170-

  • Model: AP-S3000W


1.Pure sine wave output

2.CPU control technology; SCM control
3.Strong ability of impact resistance
4.Have UPS function and AC charger function
5.Wide input voltage range: 170-275V(AC220V); three step AVR (two step -up, one step -down)
6.Protection against overload, short-circuit, overvoltage, under-voltage and over-temperature, etc. 
7.Anti reverse connection protection and high-low voltage protection
8.Special overload protection: when it is overload, it will lock the unit automatically,when it restores,it will restart the unit automatically again.
9.Strong inverter ability. It can change frequency immediately and it is able to drive the inductive load such as air conditioner, refrigerator, motor, etc.
10.LCD display 

11.Meet the need of different power supply
12.Use MOSFET 
13.Mains supply priority mode/energy saving mode/battery priority mode are settable
14.Battery Type/ utility charging current(0A-35A) are settable,meeting different types of battery charging management


Model
3000W
3000W
3000W
Rated capacity
3000W
3000W
3000W
Peak Power
9000W
9000W
9000W
battery voltage
12VDC
24VDC
48VDC
Input
DC input voltage range
12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC
Mains input voltage range
AC220V:145-275VAC
Mains input frequency range
45-65HZ
Battery low voltage alarm
12VDC:10.5V 24VDC:21V 48VDC:42V
Battery low voltage protection
12VDC:10V 24VDC:20V 48VDC:40V
Battery over voltage protection
12VDC:16.7V 24VDC:33.4V 48VDC:66.8V
Battery over voltage alarm
12VDC:15V 24VDC:30V 48VDC:60V
Over power protection
110% more than rated capacity
Temperature protection
≥85℃ alarm ≥90℃ machine shut off
Output Efficiency

Output voltage (battery mode)
220VAC±2%
Output frequency (battery mode)
50/60HZ±1%
Output wave form
pure sine wave
Output voltage range (mains mode)
Stabilization output:220VAC±10%
Output voltage range (mains mode)
Tracking automatically
Transfer time
≤8ms
Display
LCD
Thermal method
Cooling fan in intelligent control
≤42℃ fan rotates slowly to ≥45℃ fan rotates fast
Working mode 
P1-p3 
inverter alarm setting
when setted to be inverter alarm ON,alarms every 2s-5s;when setted to be inverter alarm OFF,alarms every 3s-5s,it will not alarm
Charging current
0A-35A
Comnunication
Rs232


Size
450*270*205mm
Packing Size
530*350*255mm
N.W
25KG
G.W
27KG